Antennas

Manual / Guide · 2022

DeepVNA 101 / NanoVNA-F Quick Start Guide (Firmware 1.0.4)

Read the PDF ↗

Author
BH5HNU
Year
2022
Type
Manual / Guide
  • deepvna
  • nanovna-f
  • vna
  • quick-start
  • firmware

← Back to the Reference Library

DeepVNA 101 / NanoVNA-F Quick Start Guide (Firmware 1.0.4)

DeepVNA 101 / NanoVNA-F Quick start guide - FW 1.0.4 Home Menu DISPLAY TRACE MARKER FORMAT STIMULUS SCALE CALIBRATE CHANNEL RECALL RECALL 0 Select a trace to modified the format, scale and more S11 REFLECT S21 THROUGH TRANSFORM … SWEEP POINTS SAVE S1P RECALL 6 BANDWIDTH SAVE S2P < BACK < BACK CONFIG STORAGE By: BH5HNU Date: 20220321 < BACK TRACE 0 SELECT LOGMAG TRACE 1 OFF SCALE/DIV PHASE TRACE 2 REFERENCE VALUE REFERENCE POSITION ELECTRICAL DELAY DELAY TRACE 3 SMITH < BACK SWR < BACK |Z| > MORE POLAR < BACK LINEAR TOUCH CAL LIST FILES TOUCH TEST SELECT MARKER SAVE CONFIG SEARCH LANGUAGE OPERATIONS < BACK > START VERSION THRESHOLD SMITH VALUE LIN > STOP 繁體中文 BRIGHTNESS BOOT BEEP < BACK LOG > CENTER < BACK > MORE RTC SET Re+Im > SPAN TRACKING < BACK < BACK START R+Xj > EDELAY < BACK STOP R+L/C < BACK START 10.000 kHz STOP 1500.000 000 MHz If calibration is available, the CAL status will be displayed. Otherwise, it is hidden. C * is in the state where an unsaved calibration is applied(it disappears from memory when the power is turned off). C0 to C4 Indicates that the saved calibration values are applied to one of the save locations. Saved or Unsaved will change when calibration data is properly saved. RESISTANCE SEARCH < LEFT SEARCH > RIGHT 简体中文 Cx D R DEEPELEC.COM S T Handheld Vector network analyzer X groups.io/g/nanovna-f Facebook Group : NanoVNA-F Hangzhou Minghong Electronic Technology Co., Ltd. IMAG Keypad MINIUM REACTANCE Q FACTOR < BACK CENTER L/C MATCH SPAN < BACK CW FREQ 1000HZ 51 point 333HZ 101 point 100HZ 201 point TRANSFORM ON LOW PASS IMPULSE LOW PASS STEP 30HZ 301 point BANDPASS 10HZ < BACK MARKER 1 MINIMUM MARKER 2 Keypad FORMAT MARKER 3 PAUSE SWEEP < BACK START STOP CENTRE SPAN < BACK MARKER 4 NORMAL MAXIMUM < BACK < BACK DELTA < BACK CALIBRATE WINDOW VELOCITY FACTOR Keypad < BACK POWER SAVE OPEN RESET SHORT APPLY CLEAR ALL < BACK SAVE 0 LOAD … ISOLN SAVE 6 THRU < BACK DONE +1 / -8 dBm Deepelec Store < BACK -1 / -9 dBm The letters below C indicate that the following error terms have been applied. D: Directivity, R: Reflection Tracking, S: Source Match, T: Transmission Tracking and X: Isolation -10 /-13 dBm Note: RTC SET is only applicable to DeepVNA 101 < BACK -4 / -10 dBm Charge Discharge Status charging full discharging low battery Red Blink ON OFF OFF Blue OFF OFF ON Blink After turning off the power, the blue light stays on for about 40 seconds, and then goes out. 7 8 9 G 4 5 6 M 1 2 3 k 0 . ← x1 Backspace & Exit Done ENGLISH REAL MAXIMUM