Manual / Guide · 2022
DeepVNA 101 / NanoVNA-F Quick Start Guide (Firmware 1.0.5)
- deepvna
- nanovna-f
- vna
- quick-start
- firmware
Manual / Guide · 2022
DeepVNA 101 / NanoVNA-F Quick start guide - FW 1.0.5 Home Menu DISPLAY TRACE MARKER FORMAT STIMULUS SCALE CALIBRATE CHANNEL RECALL RECALL 0 Select a trace to modified the format, scale and more S11 REFLECT S21 THROUGH TRANSFORM … SWEEP POINTS SAVE S1P RECALL 6 BANDWIDTH SAVE S2P < BACK < BACK CONFIG STORAGE By: BH5HNU Date: 20221028 < BACK TRACE 0 SELECT LOGMAG TRACE 1 OFF SCALE/DIV PHASE TRACE 2 REFERENCE VALUE REFERENCE POSITION ELECTRICAL DELAY DELAY TRACE 3 SMITH < BACK SWR < BACK |Z| > MORE POLAR < BACK LINEAR TOUCH CAL LIST FILES TOUCH TEST SELECT MARKER SAVE CONFIG SEARCH < BACK LANGUAGE THRESHOLD OPERATIONS > START VERSION BOOT BEEP SMITH VALUE LIN > STOP 繁體中文 BRIGHTNESS FREQUENCY FORMAT < BACK LOG > CENTER < BACK > MORE RTC SET Re+Im > SPAN TRACKING < BACK < BACK START R+Xj > EDELAY < BACK STOP R+L/C < BACK Cx D R DEEPELEC.COM S T Handheld Vector network analyzer X groups.io/g/nanovna-f Facebook Group : NanoVNA-F Hangzhou Minghong Electronic Technology Co., Ltd. START 10.000 kHz STOP 1500.000 000 MHz If calibration is available, the CAL status will be displayed. Otherwise, it is hidden. C * is in the state where an unsaved calibration is applied(it disappears from memory when the power is turned off). C0 to C4 Indicates that the saved calibration values are applied to one of the save locations. (The lowercase letter c indicates that the calibration data is interpolated.) < BACK RESISTANCE SEARCH < LEFT SEARCH > RIGHT 简体中文 START STOP CENTRE SPAN IMAG Keypad MINIUM REACTANCE Q FACTOR < BACK CENTER L/C MATCH SPAN < BACK CW FREQ Keypad AMATEUR FREQUENCY PAUSE SWEEP 1000HZ 51 point 333HZ 101 point MARKER 1 100HZ 201 point TRANSFORM ON LOW PASS IMPULSE LOW PASS STEP MARKER 2 30HZ 301 point BANDPASS MARKER 3 10HZ < BACK MARKER 4 < BACK DELTA MINIMUM WINDOW NORMAL VELOCITY FACTOR MAXIMUM < BACK < BACK < BACK < BACK Keypad CALIBRATE POWER HAM 160m SAVE OPEN HAM 80m RESET SHORT HAM 40m LOAD HAM 30m ISOLN HAM 20m APPLY CLEAR ALL < BACK SAVE 0 … SAVE 6 THRU HAM 17m DONE > MORE < BACK < BACK < BACK +1 / -8 dBm -1 / -9 dBm The letters below C indicate that the following error terms have been applied. D: Directivity, R: Reflection Tracking, S: Source Match, T: Transmission Tracking and X: Isolation -10 /-13 dBm Note: RTC SET is only applicable to DeepVNA 101 < BACK -4 / -10 dBm Charge Discharge Status charging full discharging low battery Red Blink ON OFF OFF Blue OFF OFF ON Blink After turning off the power, the blue light stays on for about 40 seconds, and then goes out. Deepelec Store 7 8 9 G 4 5 6 M 1 2 3 k 0 . ← x1 Backspace & Exit Done ENGLISH REAL MAXIMUM